automatischer Trockenpulverfeuerlöscher / manuelle Pulverfüllmaschine / abc Pulverfüllmaschine für Feuerlöscher
Produktbeschreibung
Symptoms |
Troubles |
Corrections |
Motor doesn’t run after energization |
Leakage protector is off |
Check if leakage occurs and energized after removal |
Fuse is open or loose |
Replace and tighten |
|
Heat relay is open |
Check if damage occurs and reset by pressing the reset button |
|
Contactor is broken |
Repair or replace |
|
Control circuit is cut off |
Properly connected |
|
Leakage protector breaks after energization |
Power line connected improperly |
Have the filler and power source of three-phase four-wire system connected properly
|
Mains output of three-phase four-wire system is through one leakage protector |
Mains output of three phase four-wire system must be through one leakage protector |
|
Suction pipe doesn’t s work after operation |
Pipe and joint leak |
Repair |
End cap for filling not in place |
Be in place |
|
Suction solenoid valve is not opened |
Have it opened |
|
Manual valve not opened |
Open it |
|
Powder suction is suspended after operation |
Suction pipe is blocked |
Remove the pipe to see if it is reduced and joint blocked |
Pipe leaks |
Repair |
|
Obvious dust exists in the air main |
Filter is damaged with leakage |
Replace |
Check the filter for a second time | ||
After the motor is started, the automatic part doesn’t work |
Contactor is damaged |
Replace or repair |
Time relay is damaged |
Replace or repair |
|
The display flashes or figure is abnormal |
|
|
Sensor of the scale bench fails or the plug is loose |
Check if the welding in the plug of sensor is loose or have it tightened |
|
|
Seatic electricity in the Static electricity in the end cap for filling |
Ground wire for the Ground wire for the scale bench is not connected firmly or metal conductor is not properly fixed |
Automatic stoppage fails when the weight requirement is met |
H value is smaller than L value |
Enter H value the same way as L value and the former must be greater than the latter |
Serial No. |
Name |
Size |
Quantity |
Unit |
1 |
Powder filler |
GFM |
1 |
Unit |
2 |
Electronic scale bench |
T3806 |
1 |
Unit |
3 |
End cap for filling |
120mm |
1 |
Piece |
4 |
Suction pipe |
15mm |
4 |
Meter |
5 |
Valve |
65mm |
1 |
Piece |
6 |
Discharge outlet |
|
1 |
Piece |
7 |
Rubber gasket |
65mm |
2 |
Piece |
8 |
Plain rubber gasket |
25mm |
5 |
Piece |
9 |
Certificate of conformity |
GFM |
1 |
Copy |
10 |
Directions for use |
GFM |
1 |
Copy |